Product details
Introduction
The MTL/B burner MTL/B using the world's advanced combustion technology today, referring to the internationally and domestic standards of electromechanical integrated fully automatic split fuel burners. Methods, the control system is equipped with a continuous proportion adjustment after the load ratio regulator. When it is not equipped with a load ratio adjustment instrument, it is a two -level sliding method.
Installation Dimensions
Model | MTL1050/B |
MTL1400/B |
MTL1750/B |
MTL2100/B |
MTL2450/B |
D1 |
φ595 |
φ650 |
φ680 |
φ780 |
φ800 |
D2 |
φ660 |
φ720 |
φ720 |
φ842 |
φ842 |
D3 |
φ560 |
φ620 |
φ660 |
φ730 |
φ770 |
L1 |
350 |
360 |
360 |
350 |
350 |
L2 |
1660 |
1800 |
1790 |
1940 |
1940 |
L3 |
800 |
833 |
860 |
860 |
900 |
H1 |
850 |
900 |
950 |
1000 |
1000 |
H2 |
1345 |
1384 |
1490 |
1544 |
1544 |
A×B |
440×690 |
500×760 |
540×780 |
600×850 |
610×850 |
Product Advantage
1. The MTL/B burning device valve group, oil mouth, oil volume regulator, program controller, wind door actuator, etc. are all internationally renowned brands to ensure that the burner's performance is excellent, safe to ensure, and reliable operation.
2. The MTL/B burner has a small noise, and the exhaust emissions meet environmental protection requirements.
3. The MTL/B burner can change the rotation angle of the air in the air through the angle of the air in the whirlwind, thereby adjusting the geometric size of the flame.
4. The MTL/B burner can choose a fan to adapt to the boiler of the back pressure of different furnaces. Even if the back pressure of the furnace is high, it can maintain stable and non -pulsating combustion.
Technical parameters
Model |
MTL1050/B |
MTL1400/B |
MTL1750/B |
MTL2100/B |
MTL2450/B |
Capacity(MW) |
16.6 |
21.35 |
26.09 |
33.21 |
37.95 |
Fuel |
Light oil |
||||
Power supply |
380V 3/N/PE 50HZ |
||||
Regulation mode |
Slide two-stage or proportional control |
||||
Sequence controller |
LAL2.25/LGK16** |
||||
Ignition transformer |
2×7000V |
*The viscosity of light oil is 6cSt (1.5ºE)
*For burners that operate continuously
Flame size
The performance characteristics of MTL/B series fuel burningrs in Mtl/B series are as follows:
● Full automatic operation, wide applicable power range
● Fully automatic operation, the processes from automatic control from flameout protection, oil pressure protection, wind pressure protection, load adjustment, furnace blowing and other processes are all controlled
● Pre -blowing and sweeping the furnace
● Safe flame monitoring system
● The geometric size of the burner flame can be adjusted
● After the renovation of the corresponding part of the requirements can be adapted to the high temperature below 250 ° C to help the air.
● Easy installation, debugging and maintenance
● Siemens LMV electronic proportional adjustment system (optional)
● Fonil gas oxygen feedback adjustment is regulated to achieve energy saving (optional)
● Environmental protection and standards, ultra -low emissions (optional)
http://www.burners-china.com/